Guide
French drain depth and slope
Depth decides which water a French drain catches. Slope decides whether that water leaves. The two are tied together, because every foot of run uses up fall and pushes the outlet end of the trench deeper.
Short answer: How deep should a French drain be? Deep enough to sit below the water it must catch: 18 to 24 inches for a yard drain, 2 to 3 feet for a curtain drain, and footing level, typically 4 to 8 feet, at a foundation. Every type needs a continuous slope of at least 1 percent to its outlet.

On this page
This page covers the two numbers that are fixed before any digging starts. The trench layers and the order of work are in the French drain installation guide, and the French drains hub explains what each type of drain is for.
The rule: below the water, above the outlet
A French drain only collects water that reaches it. Water soaking down through topsoil, water moving sideways along the top of a clay layer and groundwater rising under a basement are at three different depths, and a drain set above any of them does nothing about it. So French drain depth has a lower limit set by the water.
It also has a limit set by the outlet. Water leaves by gravity, so the pipe at the discharge end must still be higher than the place it empties. A trench dug deeper than its outlet is a buried pond.
Between those two limits is the workable range, and on some lots there is none. That is the case for a dry well or a pump, covered below.
French drain depth by drain type
| Drain type | Typical depth | Trench width | What sets the depth |
|---|---|---|---|
| Yard or lawn drain | 18–24 in | 12–18 in | The depth of the soggy layer, often topsoil over clay |
| Simple DIY yard drain | 8–24 in | 10–12 in | How far below the surface the standing water sits |
| Curtain drain | 2–3 ft | 12–18 in, as for a yard drain | The layer carrying water downhill toward the lot |
| Exterior footing drain | Footing level, typically 4–8 ft | At least 16 in at the pipe, with stone 1 ft beyond the footing edge | The bottom of the foundation wall |
| Interior basement drain | Below the slab, beside the footing | A channel cut along the wall | The slab and the top of the footing |
(Sources: Louisiana State University AgCenter publication 3879 and Northern Virginia Soil and Water Conservation District for yard drain dimensions; Delaware Department of Natural Resources and Environmental Control for the 8 to 24 inch range; Building America Solution Center for footing drain trench size; International Residential Code, section R405.1, for stone at the footing.)
Yard drains
The common range is 18 to 24 inches. The U.S. Department of Energy's Building America Solution Center is slightly more specific: the pipe 18 inches or more below ground, in a trench at least 22 inches deep. Inside that trench go 4 inches of stone, the 4-inch pipe, 4 to 6 inches of stone over it, and 9 inches or more of cover.
Go shallower only when the problem is purely on the surface. Delaware's environmental agency describes simple yard drains as shallow as 8 inches, which is enough to drain a puddle through stone that runs up to grade. The yard French drain guide covers lawn drains in more detail.
Curtain drains
A curtain drain runs across a slope, uphill of the area it protects, and cuts off water moving through the ground toward it. It has to reach down to the layer that water is traveling in, which is why it runs deeper than a lawn drain, at 2 to 3 feet. Dig a test hole first and note the depth at which water seeps in from the uphill side. The drain has to reach at least that deep.
Footing drains
At a foundation, the depth is not a choice. The International Residential Code, section R405.1, requires drains around concrete or masonry foundations that retain earth and enclose usable space below grade, installed at or below the top of the footing or below the bottom of the slab. The stone must extend at least 1 foot beyond the outside edge of the footing and 6 inches above its top. The pipe sits on at least 2 inches of washed stone and is covered by at least 6 inches. The code exempts foundations on well-drained sand and gravel soils.
Footing level is typically 4 to 8 feet down, and commonly 6 to 8 feet under a full basement. The drain goes beside the footing, not below its base. Digging lower than the bottom of a footing right next to it takes away soil the footing bears on, which is how a drainage job undermines the wall it was meant to protect. The exterior foundation drain guide covers the excavation, and the interior basement drain guide covers the version built from inside.
Trench width
Width follows from the pipe. A 4-inch pipe needs stone on both sides to collect water and hold the pipe in place, so the published widths run three to four times the pipe diameter. The Building America guidance gives 14 inches for a yard drain and 16 inches for a footing drain, the second figure leaving 6 inches of stone around the pipe. Louisiana State University AgCenter gives 12 to 18 inches for a homeowner drain.
A wider trench is not a better drain in proportion to its cost. Width adds storage and adds stone. Going from 12 to 18 inches wide increases the stone order by half. Use the French drain gravel calculator to see what a change in width or depth does to the tonnage before settling on a size.
French drain slope: the 1 percent minimum
The minimum French drain slope is 1 percent. That is 1 foot of fall for every 100 feet of run, about 1 inch every 8 feet, or 1/8 inch per foot. The International Residential Code, section P3005.3, sets the same 1/8 inch per foot as the minimum for gravity drain piping 3 inches and larger.
| Length of run | Minimum fall | Depth at the outlet end |
|---|---|---|
| 25 ft | 3 in | 21 in |
| 50 ft | 6 in | 24 in |
| 75 ft | 9 in | 27 in |
| 100 ft | 12 in | 30 in |
| 150 ft | 18 in | 36 in |
The slope does two things. It moves the water, and it moves the silt. Water crawling through a nearly level pipe drops whatever it is carrying, and the deposit builds from the low spots outward. NRCS Conservation Practice Standard 606 sets the minimum grade for subsurface drains by the flow velocity needed to keep them clean, and requires a higher velocity where fine sand and silt are present.
Three rules follow:
- Continuous beats steep. A drain at a steady 1 percent works. A drain that averages 2 percent with one sag in it holds water at the sag permanently.
- More is fine. If the ground gives 2 or 3 percent, take it. On steep ground, protect the outlet with stone, because the water arrives faster.
- Slope the trench, not just the pipe. The pipe rests on the stone bedding, and the bedding follows the trench bottom. All three fall together.
How to measure the slope
Slope as a percentage is fall divided by run, times 100, with both in the same unit. A trench that drops 9 inches over 60 feet falls 0.75 feet in 60, which is 1.25 percent.
Before digging: find out how much fall the lot has. Drive a stake at the wet area and another at the planned outlet. Tie a string to the first stake at ground level, pull it to the second and level it with a line level or a laser. The height of the string above the ground at the outlet stake is the drop in the surface between the two points.
For the pipe to come out at the surface, that drop has to cover the depth of the pipe at the start plus the fall along the run. A 60-foot drain starting 18 inches deep needs 18 inches plus 7.2 inches of fall, so about 25 inches of drop. With less than that, the drain cannot reach daylight at that length and depth.
While digging: check the trench bottom. Leave the level string in place above the trench and measure down from it to the trench bottom every 10 feet. Each measurement should be about 1 1/4 inches greater than the last. Repeat the check on top of the bedding stone and again on top of the pipe before it is covered.
After laying the pipe: run water. Put a hose in the high end and watch the low end. A steady flow that starts promptly and leaves nothing standing in the pipe confirms what the tape said.
What to do on a flat lot
On level ground, the trench supplies all the fall by getting deeper, and the outlet end soon ends up below anything it could drain to. The table above shows the arithmetic: a 100-foot drain that starts 18 inches deep is 30 inches deep at the far end. Delaware's guidance says plainly that French drains are not recommended where a yard floods frequently for lack of slope. The options, from cheapest up:
- Shorten the run. Every 8 feet removed saves an inch of depth at the outlet. Drain the wet spot to the nearest workable point, not the farthest.
- Split it. Two legs falling away from a high point in the middle each need half the fall of one long run.
- Start shallower. If the water is on the surface, the drain does not need to start at 18 inches.
- End at a dry well. A buried stone-filled pit lets the water soak away below the level of the pipe. It works only in soil that drains, so test the infiltration rate first. The Building America guide describes a pit 4 feet square and 4 to 6 feet deep, filled with clean rock, with the pipe entering at half its height or higher. Installed, a dry well runs $1,500 to $4,000.
- End at a pump basin. A sump collects the water and lifts it to a discharge point. A sump system runs $1,000 to $3,000 installed and needs power.
- Use the surface instead. Regrading or a shallow swale moves water with far less digging. The Building America guide gives 2 to 4 percent as the working slope for a swale.
The comparison of a French drain, a dry well and a catch basin goes through which fits which lot. Where the water is roof runoff, a rain garden can take it out of the system before any drain is needed.
Frost depth
Frost depth varies too much to give one number. The International Residential Code leaves it to each jurisdiction, which enters its local frost line in the code's climatic design table (Table R301.2), and requires footings to extend below it. Your building department can tell you the figure for your address.
That has two consequences for drains. A footing drain sits at the footing, so it is already below frost. A yard drain at 18 to 24 inches is inside the frost zone across much of the northern United States, and it does not need to be deeper for that reason alone. A drain that slopes continuously empties itself after each storm, and an empty pipe has nothing in it to freeze. The drain that freezes is the one with a sag holding water.
The outlet is the vulnerable point. NRCS Standard 606 calls for outlets to be protected where ice may damage them. Keep the opening clear of packed snow, and do not let it discharge across a walkway or driveway, where the water will freeze into a sheet.
Safety in deep trenches
A yard drain at 2 feet is a trip hazard. A footing drain at 7 feet can kill. Soil is heavy, and a trench wall gives no warning before it goes.
The federal excavation standard for construction work (OSHA, 29 CFR 1926 Subpart P) applies to employers rather than to homeowners, but it is the benchmark for what is safe:
- 5 feet. Workers in an excavation must be protected from cave-ins by sloping, shoring or a trench shield, unless the excavation is less than 5 feet deep and a competent person finds no sign of a potential cave-in, or it is entirely in stable rock (section 1926.652).
- 4 feet. A trench 4 feet or deeper needs a ladder, stairway or ramp within 25 feet of every worker (section 1926.651).
- 2 feet. Excavated soil and equipment must be kept at least 2 feet back from the edge (section 1926.651).
- Every day. A competent person inspects the excavation before work starts and after every rainstorm (section 1926.651).
For a homeowner, the practical reading is simple. Keep the spoil pile 2 feet back on any trench. Stay out of any trench approaching 5 feet deep unless its sides are sloped back or shored. Treat anything at footing depth as contractor work. And call 811 before digging at any depth, since a yard drain works at the depths where service lines are buried.
What depth does to cost
Depth is the main price driver, because every extra foot multiplies the soil that is dug, moved and put back. The same pipe in the same stone costs $18 to $40 per linear foot installed as a yard drain, $25 to $55 as a curtain drain, and $60 to $120 as an exterior foundation drain. A footing drain at seven feet costs three to five times more per foot than a yard drain at 20 inches.
Slope affects cost through the outlet. A lot with enough fall drains to daylight for nothing. A lot without it adds a dry well or a pump to the job. The French drain cost calculator prices each combination of placement, length and outlet, and has a form to request quotes for comparison.
To see these dimensions drawn out, the French drain diagrams show the profile, the cross-section and the footing detail side by side. If the water is already reaching a basement wall, start with the diagnosis on the foundation and basement water page, because the right depth depends on which water it is. For the materials that go in the trench at any depth, see the guide to pipe, gravel and fabric.
Common questions
How deep should a French drain be in a yard?
Most yard French drains are 18 to 24 inches deep in a trench 12 to 18 inches wide. The U.S. Department of Energy's Building America guidance puts the pipe 18 inches or more below ground in a trench at least 22 inches deep and 14 inches wide. A shallower trench can still dry a surface puddle, but it will not intercept water moving below it.
What is the minimum slope for a French drain?
One percent: 1 foot of fall per 100 feet of run, or about 1 inch every 8 feet. That matches the 1/8 inch per foot that the International Residential Code sets for gravity drain piping 3 inches and larger. The slope has to be continuous. A drain that averages 1 percent but has a dip in it holds water at the dip.
Can a French drain be too deep?
Yes, in two ways. A trench that is deeper than its outlet cannot drain by gravity and needs a pump or a dry well. And a trench dug beside a house to below the bottom of the footing can undermine the foundation. Past 5 feet, federal construction rules also require cave-in protection for anyone working in it.
How do you slope a French drain on flat ground?
Dig the trench deeper as it runs, so the bottom falls 1 percent even though the surface is level. That works until the outlet end is too deep to reach daylight. Then the choices are a shorter or shallower drain, two legs falling away from a high point, a dry well at the low end, or a pump basin.
Does a French drain need to be below the frost line?
A footing drain is below it automatically, because footings are built below the local frost depth. A yard drain usually is not and does not need to be, as long as it slopes continuously and empties after each storm, since a pipe with no standing water has nothing in it to freeze. Keep the outlet clear of ice and snow.
How wide should a French drain trench be?
Wide enough for the pipe with stone on both sides: 12 to 18 inches for a typical yard drain with 4-inch pipe. Federal Building America guidance gives 14 inches for a yard drain and 16 inches for a footing drain, which leaves 6 inches of stone around the pipe.