spawnusa

Guide

French drain depth and slope

Depth decides which water a French drain catches. Slope decides whether that water leaves. The two are tied together, because every foot of run uses up fall and pushes the outlet end of the trench deeper.

By the spawnusa.org editors · Updated · How we price

Short answer: How deep should a French drain be? Deep enough to sit below the water it must catch: 18 to 24 inches for a yard drain, 2 to 3 feet for a curtain drain, and footing level, typically 4 to 8 feet, at a foundation. Every type needs a continuous slope of at least 1 percent to its outlet.

Engineer holding a grade rod with a laser receiver to check elevation on a graded earthen slope
Engineer holding a grade rod with a laser receiver to check elevation on a graded earthen slope. Photo: USDA Natural Resources Conservation Service, Public domain, via Wikimedia Commons

On this page

  1. The rule: below the water, above the outlet
  2. French drain depth by drain type
  3. Trench width
  4. French drain slope: the 1 percent minimum
  5. How to measure the slope
  6. What to do on a flat lot
  7. Frost depth
  8. Safety in deep trenches
  9. What depth does to cost

This page covers the two numbers that are fixed before any digging starts. The trench layers and the order of work are in the French drain installation guide, and the French drains hub explains what each type of drain is for.

The rule: below the water, above the outlet

A French drain only collects water that reaches it. Water soaking down through topsoil, water moving sideways along the top of a clay layer and groundwater rising under a basement are at three different depths, and a drain set above any of them does nothing about it. So French drain depth has a lower limit set by the water.

It also has a limit set by the outlet. Water leaves by gravity, so the pipe at the discharge end must still be higher than the place it empties. A trench dug deeper than its outlet is a buried pond.

Between those two limits is the workable range, and on some lots there is none. That is the case for a dry well or a pump, covered below.

French drain depth by drain type

Typical depth and trench width by type of French drain
Drain typeTypical depthTrench widthWhat sets the depth
Yard or lawn drain18–24 in12–18 inThe depth of the soggy layer, often topsoil over clay
Simple DIY yard drain8–24 in10–12 inHow far below the surface the standing water sits
Curtain drain2–3 ft12–18 in, as for a yard drainThe layer carrying water downhill toward the lot
Exterior footing drainFooting level, typically 4–8 ftAt least 16 in at the pipe, with stone 1 ft beyond the footing edgeThe bottom of the foundation wall
Interior basement drainBelow the slab, beside the footingA channel cut along the wallThe slab and the top of the footing

(Sources: Louisiana State University AgCenter publication 3879 and Northern Virginia Soil and Water Conservation District for yard drain dimensions; Delaware Department of Natural Resources and Environmental Control for the 8 to 24 inch range; Building America Solution Center for footing drain trench size; International Residential Code, section R405.1, for stone at the footing.)

Yard drains

The common range is 18 to 24 inches. The U.S. Department of Energy's Building America Solution Center is slightly more specific: the pipe 18 inches or more below ground, in a trench at least 22 inches deep. Inside that trench go 4 inches of stone, the 4-inch pipe, 4 to 6 inches of stone over it, and 9 inches or more of cover.

Go shallower only when the problem is purely on the surface. Delaware's environmental agency describes simple yard drains as shallow as 8 inches, which is enough to drain a puddle through stone that runs up to grade. The yard French drain guide covers lawn drains in more detail.

Curtain drains

A curtain drain runs across a slope, uphill of the area it protects, and cuts off water moving through the ground toward it. It has to reach down to the layer that water is traveling in, which is why it runs deeper than a lawn drain, at 2 to 3 feet. Dig a test hole first and note the depth at which water seeps in from the uphill side. The drain has to reach at least that deep.

Footing drains

At a foundation, the depth is not a choice. The International Residential Code, section R405.1, requires drains around concrete or masonry foundations that retain earth and enclose usable space below grade, installed at or below the top of the footing or below the bottom of the slab. The stone must extend at least 1 foot beyond the outside edge of the footing and 6 inches above its top. The pipe sits on at least 2 inches of washed stone and is covered by at least 6 inches. The code exempts foundations on well-drained sand and gravel soils.

Footing level is typically 4 to 8 feet down, and commonly 6 to 8 feet under a full basement. The drain goes beside the footing, not below its base. Digging lower than the bottom of a footing right next to it takes away soil the footing bears on, which is how a drainage job undermines the wall it was meant to protect. The exterior foundation drain guide covers the excavation, and the interior basement drain guide covers the version built from inside.

Trench width

Width follows from the pipe. A 4-inch pipe needs stone on both sides to collect water and hold the pipe in place, so the published widths run three to four times the pipe diameter. The Building America guidance gives 14 inches for a yard drain and 16 inches for a footing drain, the second figure leaving 6 inches of stone around the pipe. Louisiana State University AgCenter gives 12 to 18 inches for a homeowner drain.

A wider trench is not a better drain in proportion to its cost. Width adds storage and adds stone. Going from 12 to 18 inches wide increases the stone order by half. Use the French drain gravel calculator to see what a change in width or depth does to the tonnage before settling on a size.

French drain slope: the 1 percent minimum

The minimum French drain slope is 1 percent. That is 1 foot of fall for every 100 feet of run, about 1 inch every 8 feet, or 1/8 inch per foot. The International Residential Code, section P3005.3, sets the same 1/8 inch per foot as the minimum for gravity drain piping 3 inches and larger.

French drain depth and slope, side viewLong section along a drain: the trench bottom falls steadily from the high end to an outlet that discharges at daylight.DepthRun: fall at least 1 ft for every 100 ft (1%)Cleanout riser at the high endTrench bottom falls steadily:no dips for silt to settle inOutlet at daylight,lower than the pipe start
Side view along the drain: a steady fall of at least 1 foot per 100 feet from the high end to the outlet.
Fall needed at 1 percent, and depth at the outlet end for a drain that starts 18 inches deep under level ground
Length of runMinimum fallDepth at the outlet end
25 ft3 in21 in
50 ft6 in24 in
75 ft9 in27 in
100 ft12 in30 in
150 ft18 in36 in

The slope does two things. It moves the water, and it moves the silt. Water crawling through a nearly level pipe drops whatever it is carrying, and the deposit builds from the low spots outward. NRCS Conservation Practice Standard 606 sets the minimum grade for subsurface drains by the flow velocity needed to keep them clean, and requires a higher velocity where fine sand and silt are present.

Three rules follow:

How to measure the slope

Slope as a percentage is fall divided by run, times 100, with both in the same unit. A trench that drops 9 inches over 60 feet falls 0.75 feet in 60, which is 1.25 percent.

Before digging: find out how much fall the lot has. Drive a stake at the wet area and another at the planned outlet. Tie a string to the first stake at ground level, pull it to the second and level it with a line level or a laser. The height of the string above the ground at the outlet stake is the drop in the surface between the two points.

For the pipe to come out at the surface, that drop has to cover the depth of the pipe at the start plus the fall along the run. A 60-foot drain starting 18 inches deep needs 18 inches plus 7.2 inches of fall, so about 25 inches of drop. With less than that, the drain cannot reach daylight at that length and depth.

While digging: check the trench bottom. Leave the level string in place above the trench and measure down from it to the trench bottom every 10 feet. Each measurement should be about 1 1/4 inches greater than the last. Repeat the check on top of the bedding stone and again on top of the pipe before it is covered.

After laying the pipe: run water. Put a hose in the high end and watch the low end. A steady flow that starts promptly and leaves nothing standing in the pipe confirms what the tape said.

What to do on a flat lot

On level ground, the trench supplies all the fall by getting deeper, and the outlet end soon ends up below anything it could drain to. The table above shows the arithmetic: a 100-foot drain that starts 18 inches deep is 30 inches deep at the far end. Delaware's guidance says plainly that French drains are not recommended where a yard floods frequently for lack of slope. The options, from cheapest up:

The comparison of a French drain, a dry well and a catch basin goes through which fits which lot. Where the water is roof runoff, a rain garden can take it out of the system before any drain is needed.

Frost depth

Frost depth varies too much to give one number. The International Residential Code leaves it to each jurisdiction, which enters its local frost line in the code's climatic design table (Table R301.2), and requires footings to extend below it. Your building department can tell you the figure for your address.

That has two consequences for drains. A footing drain sits at the footing, so it is already below frost. A yard drain at 18 to 24 inches is inside the frost zone across much of the northern United States, and it does not need to be deeper for that reason alone. A drain that slopes continuously empties itself after each storm, and an empty pipe has nothing in it to freeze. The drain that freezes is the one with a sag holding water.

The outlet is the vulnerable point. NRCS Standard 606 calls for outlets to be protected where ice may damage them. Keep the opening clear of packed snow, and do not let it discharge across a walkway or driveway, where the water will freeze into a sheet.

Safety in deep trenches

A yard drain at 2 feet is a trip hazard. A footing drain at 7 feet can kill. Soil is heavy, and a trench wall gives no warning before it goes.

The federal excavation standard for construction work (OSHA, 29 CFR 1926 Subpart P) applies to employers rather than to homeowners, but it is the benchmark for what is safe:

For a homeowner, the practical reading is simple. Keep the spoil pile 2 feet back on any trench. Stay out of any trench approaching 5 feet deep unless its sides are sloped back or shored. Treat anything at footing depth as contractor work. And call 811 before digging at any depth, since a yard drain works at the depths where service lines are buried.

What depth does to cost

Depth is the main price driver, because every extra foot multiplies the soil that is dug, moved and put back. The same pipe in the same stone costs $18 to $40 per linear foot installed as a yard drain, $25 to $55 as a curtain drain, and $60 to $120 as an exterior foundation drain. A footing drain at seven feet costs three to five times more per foot than a yard drain at 20 inches.

Slope affects cost through the outlet. A lot with enough fall drains to daylight for nothing. A lot without it adds a dry well or a pump to the job. The French drain cost calculator prices each combination of placement, length and outlet, and has a form to request quotes for comparison.

To see these dimensions drawn out, the French drain diagrams show the profile, the cross-section and the footing detail side by side. If the water is already reaching a basement wall, start with the diagnosis on the foundation and basement water page, because the right depth depends on which water it is. For the materials that go in the trench at any depth, see the guide to pipe, gravel and fabric.

Common questions

How deep should a French drain be in a yard?

Most yard French drains are 18 to 24 inches deep in a trench 12 to 18 inches wide. The U.S. Department of Energy's Building America guidance puts the pipe 18 inches or more below ground in a trench at least 22 inches deep and 14 inches wide. A shallower trench can still dry a surface puddle, but it will not intercept water moving below it.

What is the minimum slope for a French drain?

One percent: 1 foot of fall per 100 feet of run, or about 1 inch every 8 feet. That matches the 1/8 inch per foot that the International Residential Code sets for gravity drain piping 3 inches and larger. The slope has to be continuous. A drain that averages 1 percent but has a dip in it holds water at the dip.

Can a French drain be too deep?

Yes, in two ways. A trench that is deeper than its outlet cannot drain by gravity and needs a pump or a dry well. And a trench dug beside a house to below the bottom of the footing can undermine the foundation. Past 5 feet, federal construction rules also require cave-in protection for anyone working in it.

How do you slope a French drain on flat ground?

Dig the trench deeper as it runs, so the bottom falls 1 percent even though the surface is level. That works until the outlet end is too deep to reach daylight. Then the choices are a shorter or shallower drain, two legs falling away from a high point, a dry well at the low end, or a pump basin.

Does a French drain need to be below the frost line?

A footing drain is below it automatically, because footings are built below the local frost depth. A yard drain usually is not and does not need to be, as long as it slopes continuously and empties after each storm, since a pipe with no standing water has nothing in it to freeze. Keep the outlet clear of ice and snow.

How wide should a French drain trench be?

Wide enough for the pipe with stone on both sides: 12 to 18 inches for a typical yard drain with 4-inch pipe. Federal Building America guidance gives 14 inches for a yard drain and 16 inches for a footing drain, which leaves 6 inches of stone around the pipe.